Products


+
  • 04(1712124025228).png
  • 03(1712124025293).png

Full power
4.xMW


Product Classification:

Full Power Wind Converter

Key Words: Converter

Online Message

Product Introduction

power 4.0MW 4.2MW 4.5MW
model HD05FP4000 HD06FP4200 HD06FP4500
Dimensions (W*H*D) 2500*2200*1600mm 2900*2200*1200mm 2900*2200*1200mm
Operating altitude 0~2000m 0~2000m 0~2000m
efficiency ≥98% ≥98% ≥98%
noise <80dB (reference value) <80dB (reference value) <80dB (reference value)
Working temperature -30℃~+45℃ (Water temperature is above 45℃, the capacity is reduced by 2%/℃, and the machine 'will be shut down at 50℃) -30℃~+45℃ (Water temperature is above 45℃, the capacity is reduced by 2%/℃, an♠d the machine will be shut down at 50℃) -30℃~+45℃ (Water temperature is above 45℃, the capacity is reduced by 2%/℃, and the machine will £be shut down at 50℃)
cooling method Liquid Cooling Liquid Cooling Liquid Cooling
Protection level Grid cabinet IP23
Control cabinet IP54
Power cabinet IP23
Grid cabinet IP23
Control cabinet IP54
Power cabinet IP23
Grid cabinet IP23
Control cabinet IP54
Power cabinet IP23
Grid parameters
power voltage 900V±10% 1140V±10% 1140V±10%
Frequency Range 47.5Hz~52.5Hz 47.5Hz~52.5Hz 47.5Hz~52.5Hz
Grid-side converter parameters
Rated Capacity 4070kW 4350kW 4660kW
Rated current 2610A 2400A 2360A
Machine measurement of converter parameters
Rated Capacity 4200kW 4350kW 4700kW
Rated current 1552A 2400A 2743A
DU/DT ≤1400V/us ≤1000V/us ≤1000V/us

 

 

The control circuit of the converter separates the loop control circuit and the clo↓sed loop control circuit according to the control mode. The former is ma¥inly used in some special equipment with low requirements; →the latter has the function of automatic control and ad♥justment, and is widely used in various working machin es.
According to the nature of the control signal, it is divided into analog control circuit and digitπal control circuit. Analog signal is the most commonly used DC voltage and current, ✔easy to use the method of electricity to be processe¶d and transformed; digital signal is a set of information parameters with dis♠crete values of the discontinuous change of the signal. Digital control has high prσecision, but the circuit is more complex and expensive. Therefore, digital-analog hy brid control circuits are widely used in practice. In addition, the control circuit using¥ the microcomputer also has many advantages.

Related Products

215/233kWh<br />C&I Energy Storage System

<ul> <li>High efficient single cluster management</li> <li>High efficient h eat management technology extending system lifespan</li> <li>High quΩality cell in high consistency with cell health big dat∑a management</li> <li>Multi-stage protection, suitable for multi-sc¶enario applications</li> <li>Modular design, high energy density, sma♥ll footprint, easy for operation and maintainance</li>​; <li>Intelligent monitoring, fast fault posi‌tioning</li> <li>Multiple operation mode optional</li> <li&​gt;Flexible parallel connection and easy system expansi≠on, eliminating DC circulating current and reducing paral§lel capacity loss</li> </ul>

630kW Centralized PCS

<ul> <li>Wide DC bus voltage range</li> <li>Inte↓lligent multi-grade fan speed regulation, no derating from -30℃to +50℃</li> <li>All aro und the clock ground insulation monitoring, ensuring the safety€ of thesystem</li> <li>Intelligent wave recording and local touch screen monitor↔ing, fast incident and fault positioning</li> <li>Flexible parallel connect<ion and easy system expansion</li> <li>Compatiblβe with various batteries</li> <li>Smooth switch between Grid and Off-gri↓d mode, "black start" function integrated</li> <li>‌;Equipped with functions like VSG, PQ , VF, etc., support L/HVRT, FRT&l₹t;/li> </ul>

2750/3150/3450kW Converter Booster Integrated Machine

<ul> <li>Wide DC bus voltage range</li > <li>All around the clock ground insulation monitoring, ensuring the ©safety of the system</li> <li>Intelligent wave recording and local touch screen moni>toring, fast incident and fault positioning</li> <Ω;li>Flexible configuration of voltage class, circuit breaker, ♣etc.</li> <li>Grid forming function, alleviate transient voltage and frequency instab→ility in the power system</li> <li>IP <55 protection on the entire body, suitable for various harsh environments</li> &l♠t;li>Support IEC 61850 protocol, rapid power response</li> </ul>

Immediate Consultation

If you are interested in our products, please leave your email,  we will contact you as soon as possible, thank you!

Submit Message